• Fengfan Non Phosphorus Degreasing Agent For Alumium And Alumium Alloy 898B
  • Fengfan Non Phosphorus Degreasing Agent For Alumium And Alumium Alloy 898B

Fengfan Non Phosphorus Degreasing Agent For Alumium And Alumium Alloy 898B

Phosphorus-free alkaline powder that lifts stamping oils and polishing compounds off aluminum without etching, before anodizing, coating or plating.
  • Fengfan Non Phosphorus Degreasing Agent For Alumium And Alumium Alloy 898B

Description

Product Overview

Fengfan 898B is a phosphorus-free alkaline powder for cleaning aluminum and aluminum alloys before anodizing, conversion coating or plating. In most industrial metal plating services that handle aluminum, it is the first wet step, and the one that decides whether everything after it holds: oil left on the surface anodizes unevenly, coats badly and fails adhesion, however well the rest of the line is run.

It is not a general-purpose alkaline cleaner with the concentration turned down. Aluminum is reactive, and a cleaner strong enough to cut heavy stamping oil will usually dull, etch or blacken it, which is why so many shops still run phosphate soak cleaners and live with the trade-off. This product takes the other route: a mild alkaline base, a surfactant blend that lifts soil quickly, and an inhibitor package that keeps the oxide film intact while the cleaning happens. It works at room temperature, so the tank does not have to be brought up to heat before the first load.

That combination is what makes it usable across a mixed workload. Polished bezels, machined housings, extrusions, heat sinks, castings and high-strength fittings can all go through the same bath, and parts reach metal electroplating, anodizing or coating bright and dimensionally unchanged rather than needing a repair polish first.

Fengfan Non Phosphorus Degreasing Agent For Alumium And Alumium Alloy 898B

Specifications

PropertyValue
Product typeAlkaline degreasing powder for aluminum and aluminum alloys
Model898B
BrandFengfan
AppearanceWhite powder
SubstrateAluminum and aluminum alloy parts; also used for mechanical parts cleaning and degreasing
Working concentration50–80 g/L
Bath temperature20–50 °C
Contact time5–20 minutes
Bath pH10–12
FormSolid powder

Product Advantages

  • Phosphorus-free chemistry that still handles hard water. The dispersants in the blend bind calcium and magnesium the way phosphates used to, so hard water does not leave scum on the work or scale in the tank. You keep the water tolerance without the phosphate load.
  • It cleans without etching. An inhibitor layer sits between the alkali and the metal, so the surfactants go after the soil while the aluminum oxide film stays intact. Polished and bright-dipped surfaces keep their reflectivity, and machined parts keep their dimensions through the cycle.
  • Oil stays in the bath, not on the part. Heavy oils are emulsified quickly and held in suspension, so they do not float back onto the work as the rack comes out, which is the usual cause of streaks and patches in a static soak line.
  • Low drag-out into the rinse and the next tank. Surface tension and viscosity are set so the film sheds quickly, which keeps the rinse cleaner, cuts the water you use, and protects the acid activation or nickel bath downstream. For shops that sell metal plating services against a reject rate, that is where the saving shows up.
  • A water-break-free surface before activation. When rinse water sheets evenly off the part instead of breaking into droplets, the surface is chemically clean. That is the condition the rest of the metal plating process assumes, and the one this cleaner is built to deliver.
  • A powder, not a liquid. It is non-toxic, non-flammable and non-explosive, dissolves completely with simple stirring, and needs no pumping, decanting or frost protection in store.

Cleaning Methods

Immersion and soak cleaning. The workhorse format: parts on racks or in baskets, the bath moved by air, by a pump or by shifting the load. It takes almost any geometry and the largest parts, and it is the easiest format to control because nothing stands between the bath and the surface.

Ultrasonic cleaning. Use it when the soil sits where a brush cannot reach: blind holes, fine threads, stacked stampings, porous die-castings with deep pockets. Cavitation lifts soil out of recesses that a soak alone will only soften, and the cycle usually shortens with it.

Spray cleaning. For flat and large-area work such as extrusions, sheet and panels, where a conveyor carries the part through a washer and mechanical impingement does part of the job. It is the natural choice for a line that already runs a tunnel washer.

Choosing between them. Geometry decides. If the soil is trapped somewhere you cannot see, ultrasonics; if the part is flat and moving on a line, spray; everything else, immersion with movement on the rack. Whichever route you take, the surface has to be uniform before an aluminum anodizing process, a conversion coating or a plating step begins, and a properly cleaned part looks the same in all three.

One product, three formats. Because the same powder serves all three, a shop that uses several electroplating chemicals does not have to keep a separate cleaner for each washer, and a part can move between formats without a change of chemistry.

Bath Make-Up

  1. Calculate the charge from your tank volume and the working concentration, using the same arithmetic you apply to the other electroplating chemicals on the line.
  2. Fill the tank with water to somewhere between one-third and two-thirds of its working volume.
  3. Add the calculated amount of powder and stir until it has dissolved completely, with no powder left sitting on the bottom.
  4. Top up to the working volume and stir again so the concentration is even from top to bottom.
  5. Run a scrap or test part before the first production load goes in.

Bath Control & Maintenance

  • Read the pH first. Alkalinity is what does the cleaning, so pH is the number to watch. When it drops below 9, the bath is spent and needs more powder.
  • Use specific gravity for a fast concentration check. At 20 °C a working bath reads 1.030–1.036. Every additional 5 g/L of powder lifts that reading by about 0.003, so a hydrometer gives you the concentration in under a minute with no titration.
  • Replenish in small steps. Typical consumption runs 200–300 m²/kg. Heavy oil loads, long drag-in from upstream stamping and hot baths all push it toward the top of that band, so add a little, re-check and add again rather than dumping in a full charge.
  • Skim the oil before it goes back in. Oil collecting on the surface should come off with a separator or an overflow weir while it is still floating; once it emulsifies back into the bath it only adds to the load the surfactants have to carry.
  • Know when to start fresh. When the bath is heavily contaminated, when cleaning times have crept up, or when the oil layer returns within a shift, it is cheaper to dump, clean the tank and make up new than to keep dosing a spent solution.
  • Keep it inside the window. A bath that has drifted low still wets the part and looks clean, but the film it leaves shows up later as patchy adhesion or a blotchy finish. Holding pH and concentration steady is the cheapest insurance a metal plating process has.
  • The same routine as the rest of the line. If you already run gravity checks or titrations on your other electroplating chemicals, this bath fits into that routine with no new equipment.
Fengfan Non Phosphorus Degreasing Agent For Alumium And Alumium Alloy 898B

Use Scenarios

EV and power-electronics heat sinks. Stamping oils cling to fin geometry, and the fins are too thin to survive a strong alkali. The surfactants penetrate the gaps and emulsify the oil without eating into the aluminum walls, so the surface is ready for fluxing, brazing or plating. It is one of the reasons the product turns up on metal electroplating lines that run a mix of formed and machined work.

Consumer electronics chassis before anodizing. A mirror-polished laptop or phone housing cannot show a trace of hazing or pitting, and the soils here are light: fingerprints, polish residue, handling oils. A gentle inhibited cleaner lifts them and leaves the finish untouched, so parts reach the aluminum anodizing process with an unblemished surface and yield stays high where a re-polish is not an option.

Contract shops working through a mixed order book. A supervisor taking in cast housings on Monday and extruded brackets on Wednesday does not want to change chemistry between batches. One bath covers porous die-castings, wrought alloys and high-strength grades, which keeps the schedule simple in an industrial metal plating shop and cuts the number of products on the shelf.

Automotive radiators and heat exchangers. Complex internal passages, brazing residues and thin walls make this a part where aggressive cleaning shows up as leaks later. Immersion or spray with an inhibited bath cleans the passages without thinning the material.

Aerospace and high-strength fittings. Where a part carries structural load, surface integrity matters as much as cleanliness. The bath removes shop soil and handling oils without starting the pitting that a harsh alkaline cleaner can leave behind.

Related Process Chemicals

  • Sealing after anodizing. Phoenix Seal 149-L is a middle-temperature sealing agent and Phoenix Seal 149-T a medium-temperature one; both close the porous oxide layer after an aluminum anodizing process, which is where corrosion resistance and dye fastness are decided.
  • Colour and decorative finishes. Phoenix EB 204A-204B is a divalent tin salt electrolytic colouring additive for anodized aluminum, and FI-970 is a bright acid copper process for high deposit brightness on decorative work.
  • Zinc plating additives. Brightener for SZ-30B covers sulfate zinc, Bright Zinc Alkaline ZN 50 serves rack and barrel lines, and Brightener for Cyanide Free Alkaline Zinc ZN-500 covers the alkaline route.
  • Bath purification and air quality. Nickel Purify P3 treats contaminated nickel baths, and FF-116 is a chrome mist inhibitor that reduces mist above chrome tanks.
  • Surface protection. FF-4219 is a nano-protective coating for wood, stone and concrete.
  • Across the range. These plating chemicals are stocked side by side, from pretreatment through to post-treatment, which is useful when one order has to cover a whole line and not just the cleaner at the front of it.

Ordering & Delivery

ItemDetail
Minimum order quantityVaries by chemical; confirmed with our sales team for each order
Payment100% T/T in advance
Lead time2 weeks
Packing10 kg/box; 25 kg or 50 kg/bag; 20 kg, 25 kg, 30 kg or 200 kg/drum; 1,000 kg/IBC drum
ShippingPer the terms agreed in the current contract
DocumentationInspection certificate issued after delivery, stating the batch number and the warranty period
Trial lotsAvailability and terms confirmed with your sales contact

Technical Support & Model Matching

Choosing the right match is where most sourcing decisions stall. As a trading supplier, we keep one point of contact from first enquiry to after-sales: tell us what you are making and the conditions you work under, and we shortlist the closest matches from our supplier network, compare specifications and arrange samples before you commit to a bulk order. If something does not behave as expected, we work with the supplying partner on the cause and a practical fix, and stay with the case until it is settled. Email, WeChat or WhatsApp enquiries get a reply within 24 hours.

FAQ

Is it safe for all aluminum alloys?

Yes. The inhibitor package is what makes that possible: it protects the oxide film on both wrought and cast aluminum, including the 6000 and 7000 series that come up most often in industrial metal plating, so the part is cleaned without being etched or blackened. On an unfamiliar die-casting, run a trial part first, because die-cast alloys vary in how they respond to any alkaline bath.

Why does being phosphorus-free matter?

Phosphorus is a nutrient. Once it reaches a river or a treatment works it feeds algae growth, which is why many regions cap it in discharge. A cleaner without it keeps that load out of your wastewater, takes the phosphate precipitation step and its sludge out of the treatment train, and saves the cost that goes with both, which is why shops providing metal plating services have been moving away from phosphate cleaners.

What types of soil does it remove?

Mineral oils, stamping and drawing lubricants, polishing compounds, vegetable-based cutting fluids, fingerprints and general shop soil. These are the soils that cause spotting and patchy adhesion once the part moves on to the plating chemicals, and they are exactly what the surfactant blend is built to emulsify.

What operating temperature should the bath run at?

Anywhere from 20 °C to 50 °C. Most lines start at ambient and let the bath find its own level, and running toward the top of the range shortens the cycle when the soil is heavy. The window is deliberately wide, because a metal plating process rarely holds a bath at one exact temperature and the cleaner should not be the thing that limits you.

Does it need a particular tank material?

No. Standard mild steel or stainless steel tanks are suitable, because this is a mildly alkaline solution rather than an aggressive one, so no special lining, coating or packaged tank is needed. Most metal electroplating shops can put it into a tank they already have, with the normal ventilation an alkaline bath calls for.

REQUEST MORE DETAILS

Please fill out the form below and click the button to request more information about
Name
Email *
Message
Verification Code *
Click to verify
Leave a message
Name
Email *
Message
Verification Code *
Click to verify