Chloride-free hard chrome brightener for industrial metal plating: 23–26% cathode efficiency, 950–1100 HV, up to three times the deposition speed.
  • Fengfan Hard Chrome Plating Chemicals Brightener High Cathode Efficiency KCR-25

Description

Product Overview

Hard chrome is a functional coating, and the bath behind it has never been the fast part of an electro plating line. This brightener is built to change that balance. It is a single-catalyst additive for hexavalent chromium baths that raises cathode efficiency, so a larger share of the current you pay for becomes deposit instead of hydrogen, and the layer reaches a wear thickness in a fraction of the time a conventional hard chrome bath needs.

KCR-25 suits wear work rather than appearance work: hydraulic rods and cylinder bores, moulds and dies, pump shafts, rolls, guide rails, wear plates, and the reclamation of worn or undersized parts that have to be rebuilt to size with a hard, low-friction surface.

The bath is chromic acid with a sulfuric acid addition, and the brightener is the only other plating chemical it needs. There is no second component to keep in ratio with the first, which matters on a line where the same bath runs for weeks — one consumption figure to watch and one container standing at the tank.

Deposit quality starts before the tank. Degrease, rinse, activate and rinse as usual, and make sure the part enters the chrome bath with a clean, unbroken water film; a chrome layer will not cover for a poorly prepared surface. After plating, hard chrome parts are normally ground or lapped back to final tolerance, so the hardness and the crack structure of the deposit are what make that finishing step, and the service life behind it, predictable.

If you are weighing up a conversion from an existing hard chrome plating process, tell us the parts you plate, the steel you plate them in and the thickness you are aiming for, and we will confirm whether this bath fits or point you to another additive in the range.

Performance Profile

  • Cathode efficiency of 23–26%. Far more of the rectifier current is consumed by metal deposition than in a conventional hard chrome bath, so the same ampere-hours deliver more chrome, less gassing at the cathode and a quieter tank.
  • Operation above 60 A/dm². The bath takes current densities that would burn a conventional chrome bath, which buys you shorter dwell per part and room to trade current density against tank time on a busy line.
  • Two to three times the deposition speed of a conventional hard chrome plating process. Where a conventional bath needs hours to reach a wear thickness, this one reaches it in a fraction of that — the practical result is more parts per shift from the same tank footprint, and that is the difference an industrial metal plating shop notices first.
  • Chloride-free. No chloride is added, so low-current-density areas are not attacked: recesses, bore ends and the shielded side behind a shoulder come out clean instead of grey or etched.
  • Micro-hardness of 950–1100 HV. Hard enough for sliding wear, abrasion and repeated contact, and it holds that hardness through the grinding or lapping that follows plating.
  • A microcrack network of up to 400 cracks per cm. The fine pattern is deliberate. It spreads corrosion current across many small cells instead of concentrating it at a few, and it gives oil somewhere to sit on a running surface.
  • Simple plating chemicals. Chromic acid, sulfuric acid and one brightener — three figures to control, instead of a multi-component system where a drift in one hides behind the others.
  • Agree the corrosion test before you quote a number. Corrosion performance in any metal plating process depends on deposit thickness and on the crack network, and salt-spray hours only compare when substrate, thickness and test method are stated. Send us your test conditions and we will confirm what the coating should do.

Bath Composition And Operating Window

ComponentOperating rangeStandard
Chromium trioxide200–275 g/L250 g/L
KCR-25 Catalyst20 ml/L20 ml/L
Sulfuric acid2.5–4 g/L2.7 g/L
Temperature50–60 °C58 °C
Cathode current density (Dk)50–75 A/dm²60 A/dm²
Anodic current density15–30 A/dm²30 A/dm²

Standard Setpoints And Bath Make-Up

Every metal plating process has a point it is happiest at, and the standard column above is where we suggest you start: the middle of each window, with headroom on both sides so a correction never means rebuilding the bath. Charge the tank with roughly two thirds of the final volume of water, add the chromium trioxide and let it dissolve fully under circulation, then add the sulfuric acid, and only then the catalyst. Bring the bath to temperature before the first part goes in.

Where you sit inside the chromic acid window changes how the bath behaves. A leaner bath favours efficiency and deposition speed. A richer bath carries current more evenly over a complex part and stays steadier at high current density. Which end suits you depends on the geometry you plate most: deep recesses and long bores generally want the richer side, simple shafts and flat plates the leaner side.

Chrome baths evaporate, and evaporation is the most common reason a bath drifts out of specification when nobody has added anything. Top up with water to the working level, circulate, and take a Baume reading before you add more chromium trioxide. The density chart further down this product converts that reading into a chromic acid figure at both 15 °C and 60 °C, and those two numbers are not the same.

Keep the sulfuric acid and the catalyst as two separate decisions. They are separate plating chemicals doing separate jobs, and a sulfate figure that has drifted will look like a brightness problem long before anyone suspects the acid.

Catalyst Replenishment And Brightness Control

  1. On an electro plating line, track ampere-hours on the tank rather than calendar days. The reference consumption for the catalyst is 4 ml per kAh, and amp-hour records are what turn that figure into a real dosing plan for your line.
  2. When you charge a new drum of chromium trioxide, add 2.2 L of catalyst per 100 kg of chromium trioxide. This keeps the ratio right during a bulk make-up instead of forcing a large correction afterwards.
  3. Treat both figures as reference points. The amount actually needed depends on the brightness of the deposit, and the deposit is the final arbiter.
  4. Read brightness at a fixed current density on a known part rather than across a mixed load. A dull or hazy deposit at the settings you normally run supports a low catalyst; a bright deposit at the same settings means the level is fine.
  5. Before adding catalyst for dullness, confirm that chromic acid and sulfuric acid are where they should be. A drifted sulfate level produces the same symptom, and dosing catalyst on top of it wastes chemical while hiding the real cause.
  6. Watch the water line as well. Evaporation concentrates everything in the tank at once, so a brightness problem that appears after a hot weekend is often a concentration problem rather than a catalyst problem.
  7. Log the additions with amp-hours, density and temperature beside them. Two or three weeks of that record tells you the true consumption of your line far better than any nominal figure.

Temperature Control

A hard chrome bath does much of its own heating. At the current densities this process runs at, the rectifier puts a substantial heat load into the tank, and on a busy line the problem is usually cooling rather than heating. That is why temperature is a control problem here, not a set-and-forget number.

Temperature is also the variable that moves first in most metal plating processes when something drifts, so hold the whole tank at one temperature rather than the spot where the probe happens to sit. A bath that reads correctly at the thermocouple but runs cooler at the far end plates unevenly, and the difference shows up as thickness variation along a long part before it shows up on any gauge.

Both heating and cooling capacity are needed. Heat exchangers and cooling pipes in titanium, Teflon or other fluorocarbon materials resist chromic acid, and the fluid inside those pipes has to keep moving at all times, or the bath stratifies and the exchanger fouls. An automatic controller earns its place on a bath of this type: an operator watching parts cannot also be watching a thermometer.

Where you sit inside the window also shifts the balance between brightness and crack structure — running hotter tends to give a brighter, more open deposit, running cooler a harder, more closely cracked one. Pick a point, hold it, and treat any change of setpoint as a change to the deposit you qualified.

Deposition Rate By Current Density

Current density (A/dm²)Deposition rate (µm/h)
3020–35
4540–50
6050–70
7.570–90
Bath the figures describeKCR-25 catalyst in a chromic acid bath at the recommended operating conditions
Trend across the rangeA higher current density gives a higher hourly build of chrome
Where the higher rates matterWear build-up on rods, rolls, cylinder bores, moulds and worn parts being rebuilt to size
Spread within a single bandRack position, agitation and part geometry, rather than a change in the bath itself

Equipment And Line Requirements

  • Tank construction. Steel lined with PVC, or steel sprayed with vinyl chloride resin. A lead-lined tank is not suitable for this process.
  • Exhaust at the bath edge. Chromic acid mist has to be pulled away at the tank lip. Edge extraction keeps the operator zone clean and stops mist settling on neighbouring tanks and cooler surfaces.
  • Rectifier. Enough amperage for the current densities you plan, 9–15 V DC, with a ripple rate below 5%.
  • Anodes. Lead-tin alloy at 93% lead and 7% tin is the recommended grade. Other lead-tin alloys and lead-antimony alloys can also be used, and auxiliary or conformal anodes should be the same alloy as the main anodes.
  • Circulation. A well-circulated bath keeps composition and temperature even across the tank. Circulation pump and filter materials should be stainless steel or a chromic-acid-resistant plastic.
  • Jigs and contacts. On any industrial metal plating line, a poor contact that would pass at low current density will burn at the densities this bath runs at, so clean contact faces and firm jigging are part of running the process properly.

Chromic Acid Concentration And Baume Control

Chromium trioxide (g/L)Bath densityBaume at 15 °CBaume at 60 °C
1801.1316.716.7
1951.1417.815.9
2101.1518.917.0
2251.1620.018.1
2401.1721.119.1
2551.1822.120.1
2701.1923.221.0
2851.2024.221.9
3001.2125.222.7

Handling, Storage And Documentation

Chromium trioxide is a strong oxidizer and a hazardous material, and this bath is built on hexavalent chromium. Treat both with the respect the safety data sheet asks for: sealed containers, a dry store away from reducing agents, organic material, acids and heat, and local exhaust ventilation wherever the bath is open. Chromic acid mist is the main exposure route on an electro plating line, so extraction and personal protective equipment at the tank belong to the process, not to overheads.

Storage and transport follow the same logic. Keep drums closed and dry, do not stack them where they can take water, and keep them away from anything that could start a reaction. For shipment, the classification and paperwork follow the hazardous-goods rules of the destination — tell us the port and the market and we will confirm what the consignment requires before it leaves.

Documentation is handled the same way. The safety data sheet and the technical data sheet for this product are available on request. If your customer or your market asks for a specific declaration, send us the exact requirement and we will confirm what can be supplied for this product rather than leave you to assume it.

If hexavalent chromium is restricted or being phased down where you operate, raise it at the enquiry stage. We supply hexavalent chromium hard chrome chemistry, and the wider range also includes alloy processes positioned as chromium-free alternatives; it is far better to have that conversation before a bath is charged than after.

Ordering And Delivery

  • Minimum order quantity. Varies by chemical; confirmed with our sales team per order.
  • Lead time. 2 weeks.
  • Payment. 100% T/T in advance.
  • Packing. 10 kg/box; 25 kg or 50 kg/bag; 20 kg/25 kg/30 kg/200 kg/drum; 1000 kg/IBC drum.
  • Shipping. Per the terms agreed in the current contract.
  • After delivery. An inspection certificate is issued after delivery stating the batch number and warranty period.
  • Before you commit. Ask your sales contact about sample availability and the trial quantity that suits your tank, and send us the tank volume, rectifier rating and anode arrangement so the operating window can be checked against your line.

Hard Chrome And Decorative Chrome

CheckKCR-25 hard chromeCHROME 31 decorative additive
Primary jobWear resistance, dimensional rebuild and low frictionBright coverage and appearance over a nickel underlayer
Deposit buildBuilt to a wear or repair thickness, then ground or lapped to final sizeThin decorative layer; appearance is the finish
Hardness and structure950–1100 HV; microcrack network up to 400 cracks/cmNot specified as a wear layer; chosen for covering power
Current density50–75 A/dm²15–20 A/dm²
Bath chemistryChromic acid 200–275 g/L, sulfuric acid 2.5–4 g/L, KCR-25 catalyst 20 ml/LChromic acid 150–250 g/L, CHROME 31 additive 5–9 ml/L; lower chromic acid load
CoverageChloride-free bath protects low-current areas from etchingThrowing power raised by 30–60% for complex shapes
Parts that fitHydraulic rods, cylinder bores, moulds, rolls, guide rails, wear platesTrim, hardware, sanitary ware and other visible parts
Choose this whenThe part has to resist wear or be rebuilt to sizeThe part has to look bright and fully covered

Bath Maintenance And Impurity Control

  • Chloride is the impurity to keep out of this bath. Rinse thoroughly after acid activation, do not carry chloride-based cleaners into the chrome tank, and check new additions before they go in.
  • Dropped parts and loose rack contacts are a slow source of iron, copper and other metals. Fish out fallen parts promptly rather than letting them dissolve in the tank.
  • Anode sludge and trivalent chromium accumulate with amp-hours. Keep circulation and filtration running during production, and clean the tank on a planned shutdown instead of waiting for a deposit defect.
  • When brightness or coverage changes, check temperature, chromic acid concentration and sulfuric acid before adding catalyst. A dull deposit is not automatically a catalyst problem.
  • Take a bath sample for analysis when the deposit changes from one end of the rack to the other, when low-current areas grey out, or when current draw rises without a change in parts. Treat those as contamination signals.
  • Log impurity events — dropped parts, drag-in, tank cleaning, filter changes — beside the amp-hour record. That log tells you whether a deposit change came from maintenance or from the chemistry.
  • Keep the filter and circulation running across the whole tank. Stagnant pockets at the ends of a long metal plating tank are where temperature differences and contamination collect.

Technical Support & Model Matching

Choosing the right match is where most sourcing decisions stall. As a trading supplier, we keep one point of contact from first enquiry to after-sales: tell us what you are making and the conditions you work under, and we shortlist the closest matches from our supplier network, compare specifications and arrange samples before you commit to a bulk order. If something does not behave as expected, we work with the supplying partner on the cause and a practical fix, and stay with the case until it is settled. Email, WeChat or WhatsApp enquiries get a reply within 24 hours.

FAQ

How much faster will our line run with this bath?

The reference figure is two to three times the deposition speed of a conventional hard chrome plating process, and it comes from two things working together: cathode efficiency of 23–26% and the ability to run above 60 A/dm². What that becomes on your line depends on the current density you can actually apply to the part in front of you, so use the deposition rate table as the planning figure and confirm it on a trial part before you quote a cycle time to anyone.

Does our lead-lined tank have to be replaced?

Yes. This process runs in a steel tank lined with PVC or sprayed with vinyl chloride resin, and a lead-lined tank is not suitable. The anodes need the same attention: lead-tin at 93% lead and 7% tin is the recommended grade, with lead-antimony acceptable as an alternative, and auxiliary anodes should match the main anodes.

What hardness and crack structure does the deposit have?

Micro-hardness sits in the 950–1100 HV range, and the deposit carries a microcrack network of up to 400 cracks per cm. The cracks are intentional — they spread corrosion current over many small cells and hold oil on a running surface — so do not read a cracked deposit as a defect until you have checked it against the specification you set.

Why does it matter that the process is chloride-free?

Chloride attacks steel where current density is lowest: inside recesses, at bore ends and on the side of a part facing away from the anode. With no chloride in the bath those areas come out clean, which is what lets you put complex parts on the same line as simple shafts. Keep chloride-bearing drag-in low at the same time — rinse properly after acid activation and before the part enters the chrome tank.

Is this the right additive for decorative bright chrome?

No. This is a hard chrome brightener for functional coatings: wear resistance, hardness and dimensional build-up. Decorative chrome depends on a different additive whose job is coverage and appearance over a nickel layer. Tell us which finish you are aiming for and we will point you to the right product instead of letting you trial the wrong one.

How do we check chromic acid concentration during production?

Take a Baume reading and correct it for temperature against the density chart in this product. The same bath reads differently at 15 °C and at 60 °C, so a reading taken hot and compared with a cold reference will send you chasing a concentration problem that does not exist. Read, correct, then decide whether to add chromium trioxide or just top up with water.

REQUEST MORE DETAILS

Please fill out the form below and click the button to request more information about
Name
Email *
Message
Verification Code *
Click to verify
Leave a message
Name
Email *
Message
Verification Code *
Click to verify